LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
A2SCPU-S1 CPU unit
MITSUBISHI A2SCPU-S1 Manual And Instructions
A2SCPU-S1 datasheetPDF datasheet
A2SCPU-S1 Common InstructionsProgramming Manual
A2SCPU-S1 User's Manual
A2SCPU-S1 Dedicated InstructionsProgramming Manual
A2SCPU-S1 FundamentalsProgramming Manual

MITSUBISHI A2SCPU-S1 Product information and technical parameters:
Brand: MITSUBISHI
Name: CPU unit
Model: A2SCPU-S1
Program memory capacity 14K.
Input and output points to the maximum 512 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage.

I/O slots: 2 slots.
Outline dimension: 220*130.
CPU basic board can be plugged into 1 power modules,
1 CPU components and a maximum of 2, 3, 5, or 8 single slot size special function components and I/O components are respectively inserted and arranged.
The expansion port are arranged on the basic substrate on both sides, for connecting board for expansion A2SCPU-S1.
Up to 3 extension substrates. PLC station distance: 1Km A2SCPU-S1
Cable type: QSI-200/250.
The function of the MELSECNET interface module is to connect the main CPU PLC to the MELSECNET data communication system.
As long as the switch on the component to set, you can determine the CPU PLC is as a main station or in situ station.
There are two modules available for selection: one is the connection of the optical cable network and the network of the coaxial cable A2SCPU-S1.
For a ANSCPU, up to only a piece of interface components can be inserted, A2ASCPU can be inserted 2.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment A2SCPU-S1.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations.
In the case of the computer for the PLC handheld programmer compile user program.
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programmming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-tto-one correspondence between the ladder diagram and the ladder diagram A2SCPU-S1 A2SCPU-S1. Its characteristics are basically consistent with the ladder diagram language.


...More relevant models >>>>