A2USCPU-S1 CPU unit
MITSUBISHI A2USCPU-S1 Manual And Instructions
A2USCPU-S1 datasheetPDF datasheet
A2USCPU-S1 Common InstructionsProgramming Manual
A2USCPU-S1 User's Manual
A2USCPU-S1 User's Manual
A2USCPU-S1 Dedicated InstructionsProgramming Manual
A2USCPU-S1 FundamentalsProgramming Manual

MITSUBISHI A2USCPU-S1 Product information and technical parameters:
Brand: MITSUBISHI
Name: CPU unit
Model: A2USCPU-S1

SRAM+E2PROM memory card.
RAM capacity: 512KB.
E2PROM capacity: 512KB. SRAM+E2PROM memory card.
RAM capacity: 32KB.
E2PROM capacity: 32KB. Input voltage: AC100-240V.
Rated output: DC5V, 3A and DC24V, 0.6A.
The power supply module is connected with the external power supply, and the DC5V is provided with the AnS programmable controller,
They are inserted in the slot of the special power supply component on the base board,
The output of the DC5V is powered by the power supply on the substrate to the component A2USCPU-S1 A2USCPU-S1
The input voltage of the component is related to the selected model.
A1S61PN/62PN has Deng generation A1S61P/A1S62P, A1S61PEU/A1S62PEU. Ethernet Ethernet module 10BASE-T/10BASE5.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian A2USCPU-S1.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A2USCPU-S1. Output type: transistor drain.
Output points: 16 points.
Load voltage: DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input coombination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A2USCPU-S1.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic A2USCPU-S1.
And the control principle is decentralized, centralized and hybrid control three.