LK Automation Limited LK Automation Limited
Brand Sort: MITSUBISHI
Home >> Price
MITSUBISHI Q172DCPU-S1 Price
MITSUBISHI Q172DCPU-S1
Type: MR-J series.
Rated output: 1.0KW.
Applicable motor series: HA-FF, HA-SE.
Voltage: three phase AC220V.
It is very helpful to improve the stability of the low speed control of the servo motor.
But there is no direct effect to improve the accuracy of position control.
There are, of course, software compensation that is similar to pitch compensation,
Can improve the physical resolution of the single lap, so as to improve the accuracy of positioning control Q172DCPU-S1
This can be effectively used in the use of the robot control of the indexing table.
It is also because of the application of splicing technology,
The rotary encoder will be more widely used in the high precision servo control in the harsh environment.
The use of rotary encoder with 224/ in the servo motor has been used in the servo motor.
Encoder serial communication system, the communication frequency can only be limited to 10M. Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Q172DCPU-S1 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=Q172DCPU-S1&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
CPU unit
A2UCPU-S1
MITSUBISHI CPU unit A2UCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A1SCPU-S1
MITSUBISHI CPU unit A1SCPU-S1
Program memory capacity: 8k. Input / out
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. In