Power supply: 120mA DC5V (PLC internal power supply), 160mA DC24V.
Analog output points: 4 points.
Voltage output: DC-10~10V.
Current output: DC0~20mA, 4~20mA.
Weight: 0.2kg.
Dimensions: 55 x 90 x 87.
The resolution of the 4 channel is 15bit binary + symbol 1bit (voltage),
High precision analog output module of 15bit binary (current).
Each channel voltage output (DC-10~10V) or current output (DC0~20mA, DC4~20mA) can be specified,
Mixed use
FA-TH16YRA20
With the form of the output and the upper and lower values and other rich features.
FX3UC-4AD can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Cable 0.6m for the expansion of the floor, the expansion of a floor for every 1 units.Output: 16 points.
Function: transistor output models (source type).
Corresponding models: FX3GA, FX3G, FX3GE, FX3GC, FX3U, FX3UC.
Can carry on the FX3GC, the FX3UC basic unit and the expansion module or the localization module the connector and the terminal station transformation,
Save the time of the input and output connection, realize the labor saving.
The use of built-in input and output components models,
Can receive AC100V input, or through the relay or the transistor to drive large capacity load. PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.