FA-TH16X100A31 Terminal module
MITSUBISHI FA-TH16X100A31 Manual And Instructions
FA-TH16X100A31 datasheetPDF datasheet

MITSUBISHI FA-TH16X100A31 Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16X100A31
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.15A.
Weight: 0.12kg.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function FA-TH16X100A31. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module FA-TH16X100A31 Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. "Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet FA-TH16X100A31.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators FA-TH16X100A31.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "DB A20 AnyWire master station.
Transmission distance: the longest 3km.
Data input and output: up to 1024 points.
Connect up to 128 units.
Enter 512 points, 512 points out of the output.
Support environmental protection, high speed, long distance transmission and special distribution system to support the special flat cable, universal VCTF cable, universal single wire cable and other cable.
Using original transmission mode, there is almost no branch limit,
Supports the automatic track and ring transmission,
Can also create suitable for small and medium sized factory wiring system.
Support remote I/O, analog quanntity, temperature and humidity terminal, anti false operation terminal and other equipment FA-TH16X100A31.
Up to 128 units from the station module
Can connect up to 128 units from the station module, for up to 1024 points (input 512 points / outputt 512 points) of the I/O control FA-TH16X100A31.
In addition, the parameters can be set through the switch, easy to set the transmission distance of 50m/200m/1km/3km.