LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TH16X24D31 Terminal module
MITSUBISHI FA-TH16X24D31 Manual And Instructions
FA-TH16X24D31 datasheetPDF datasheet

MITSUBISHI FA-TH16X24D31 Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16X24D31
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Output points: 16 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points) FA-TH16X24D31.
External wiring connection: 18 point terminal FA-TH16X24D31
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch FA-TH16X24D31.
Communication protocol is a standard Modbus protocol or custom protocol. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module FA-TH16X24D31.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime. Convert connectors to e-CON.SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H module FA-TH16X24D31.
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
In addition, the module can be useed for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed FA-TH16X24D31.


...More relevant models >>>>