Motor series: medium inertia, medium power.
Rated output power: 2.0kw.
Rated speed: 3000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: medium inertia from low speed to high speed three modes for selection, suitable for different applications.
Application examples: transmission machinery, robots, X-Y working platform.
High resolution encoder 131072p/rev (17 bit)
FR-F740-11K-CHT
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 7.0kw.
Interface type: SSCNET type III fiber communication.
Power specification: three phase AC400V.
High speed serial communication between the SSCNET and the servo amplifier by using the fastest up to 0.44ms communication cycle,
A fully synchronous control system can be constructed.
It is only necessary to insert the special optical fiber into the joint to form SSCNET III network, which greatly reduces the wiring work and reduces the possibility of false wiring.
Due to the adoption of the optical fiber communication, the anti noise ability can be greatly improved and the long distance wiring of 50 meters (maximum 800 meters x 16 axes) can be realized.
A servo amplifier to meet the full closed loop control function MR-J3-B-RJ006.
Suitable for mechanical servo optimization and adjustment!
More advanced optimization adjustment function and control function to maximize mechanical properties. SI/QSI/H-PCF/ wide H-PCF optical cable double loop PC (control station / common station) / remote I/O network (remote master station). With external power supply function.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
FR-F740-11K-CHT Operation manual/Instructions/Model selection sample download link: