The length of the line: 10M.
IP level: IP65.
Cable lead out direction: motor shaft different side.
Bending life: standard.
The cable is not shielded.
Encoder with cable (motor side); for HF-KP/HF-MP series (motor shaft with side extraction). Motor: HA-LH type.
Power: 3.5kw.
Speed: 2000r/min.
According to the types of power supply: can be divided into DC motor and AC motor.
The structure and working principle of DC motor can be divided into four parts: brushless DC motor and brushless DC motor
FR-ABR-H3.7K
Brushless DC motor can be divided into: permanent magnet DC motor and DC motor.
DC Motor Division: Series DC motor, DC motor, DC motor and DC motor.
Permanent magnet DC Motor Division: rare earth permanent magnet DC motor, ferrite permanent magnet DC motor and aluminum nickel Gu Yongci DC motor. Output: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000.
Output DC0~20mA; DC-12~12V.
Conversion speed: 10ms/1 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 4 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
FR-ABR-H3.7K Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-ABR-H3.7K&select=5