Functional security based on EN954: category 4.
Functional security based on SIL3: IEC61508.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file.
Transmission speed: 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps (automatic tracking).
Station No.: 1~64 station.
External connection mode: 2 pieces of spring clip terminal.
Spring clip terminal.
The safety controller can communicate with the master station of the CCLINK system.
The data from the security controller to the master station can be edited by the parameters WS0-4RO.
The security controller receives the data from the master station to set the tag name
WS0-4RO
Transmission speed according to the automatic tracking station, do not need to set the transmission speed.
By using the spring clamping terminal, the wiring time and the maintenance time of the CC-Link cable can be reduced.
No need to re write parameters after replacement of the module WS0-4RO.
The security controller can be set up and connected with the monitoring software.
Confirm the error record that is detected. Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system WS0-4RO.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down. Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure WS0-4RO.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connecttion settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file WS0-4RO.