LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
RX41C6HS Extension module
MITSUBISHI RX41C6HS Manual And Instructions
RX41C6HS datasheetPDF datasheet

MITSUBISHI RX41C6HS Product information and technical parameters:
Brand: MITSUBISHI
Name: Extension module
Model: RX41C6HS

Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range RX41C6HS.
Sensor input when the action: according to the scale of the processing RX41C6HS
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control RX41C6HS.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points RX41C6HS.
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy.
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply capacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set.
Can be divided into 5 groups. Input: DC input.
Input points: 32 points.
Rated input voltage: DC24V
Rated input current: 4 TYP.
Response time: 0.1 ~ 70ms.
Common way: 32 points, the public side.
Interrupt function: have.
Output: Transistor (drain type) output.
Output points: 32 points
Rated load voltage: DC12 ~ 244V RX41C6HS.
Max load current: 0.2A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat)
Common。
External wiring connection: 40 pin connector two.
1 input / output hybrid modules can meet the functiional requirements of both input and output modules RX41C6HS.
The function of the 2 modules is concentrated in 1 modules, which can help to save space and cost.