RD62D2 High speed counter module
MITSUBISHI RD62D2 Manual And Instructions
RD62D2 datasheetPDF datasheet

MITSUBISHI RD62D2 Product information and technical parameters:
Brand: MITSUBISHI
Name: High speed counter module
Model: RD62D2
Differential input, transistor (drain type) output.
Channel number: 2CH.
External wiring connection mode: 40 pin connector
Count input signal: there
Single phase input (single frequency / double frequency)
Dual phase input (single frequency and double frequency /4)
CW/CCW input: there
The signal level (phi A, Phi B): EIA standard RS-422-A differential line driver level.
PWM output function can be output through the highest frequency of 200kHz, minimum ON 100ns width of the PWM waveform of any duty cycle.
In addition, the output cycle and duty cycle can be changed when the output PWM,
The use of the most suitable for the use of continuous PWM signal flow control.

Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 1200K (security program: 40K).
Program memory: 4800K.
Soft element / tag memory: 3370K.
Data memory: 40M.
Unified program development environment RD62D2.
Whether the general control procedures or safety control procedures, can be integrated into 1 Engineering documents,
Unified management by Works3 GX RD62D2 The troublesome operation can save more than one project file management.
When you create a security control program, you are also the same as when you create a general control program,
Various features of GXWorks3 can be developed using the support program RD62D2.
Improve production efficiency through high responsiveness and rich program capacity.
Efficient use of high performance iQ-R CC-Link series and IE Field MELSEC networks,
Improve responsiveness and improve production efficiency.
In addition, the security control program capacity increased to 40K, about 3 times in the past.
Safe CPU can be used to deal with complex large capacity programs RD62D2. Operation control mode: stored procedure repeated operation.
Input / output points: 4096 points.
Program capacity: 1200K.
As the core of the programmable controller control system, programmable controller CPU module has been equipped with a variety of functions,
Support multiple controls. Program capacity from the 40K step to the 1200K step, to select the most suitable system size of the CPU module.
And the CPU module can be directly connected to the industrial network, which can reduce the construction cost of the system.
Soft element / label area for easy processing
The extended SRAM card is installed on the programmable controller CPU module,
Soft element / label sttorage area with up to 5786K words RD62D2.
The expansion area is connected to the memory of the built-in CPU module,
The range of soft components / labels can be freely distributed.
Therefore, it can be easily programmed without taking into account the boundaries of each storage area RD62D2.
In addition, can also use the SD memory card processing records data, database data, such as large capacity data.