R60DAI8 Analog output module
MITSUBISHI R60DAI8 Manual And Instructions
R60DAI8 datasheetPDF datasheet

MITSUBISHI R60DAI8 Product information and technical parameters:
Brand: MITSUBISHI
Name: Analog output module
Model: R60DAI8
Analog output channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Conversion speed: 80 s/CH.
Channel to channel insulation
Output short circuit protection: have.
External power supply: DC24.
External wiring connection mode: 18 point screw terminal.
Voltage output
Digital input value: -.
Analog output voltage: -.
Current output
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
Without using a special program to create the waveform, can reduce the programming time.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.

"Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 7.0mA.
Response time: 0.1 ~ 70ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing R60DAI8.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs R60DAI8
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors R60DAI8.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented R60DAI8.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "Main base plate, extended substrate mounting.The input and output module installation number: 8.
DIN guide rail mounting adapter type: R6DIN1.
Size (H) * (32.5mm) * (W) * (D): * 328mm * 101mm. "1Gbps, fiber optic cable, management station / general station.
IE CC-Link controller network is a kind of controller network based on Gigabit Ethernet,
The most suitable for large scale controller decentralized control.
With high speed (1Gbps), large capacity (128K word), using the characteristics of the dual loop fiber,
Controller network system capable of constructing high reliability.
The fault prone high reliability fiber double loop network is not easy to be transmitted by using the double loop transmission of the strong anti interference fiber cable,
In the event of cable disconnection or power failure, etc., but also through the ring back function to continue communication.
Quick find line fault,, module exception
The overall situation of the IE CC-Link controller network can be visualized by engineering software, and the circuit fault and module exception can be found quickly R60DAI8.
Therefore, in case of failure, can quickly identify abnnormal parts, in order to shorten the system down time R60DAI8.
In addition, the network can also monitor the status of other stations programmable controller.