Analog output channel number: 16CH.
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 50ppm/.
Conversion speed: 1ms/CH.
Insulation between channels: isolation transformer insulation.
Output short circuit protection: have.
External power supply: -.
External wiring connection: 40 pin connector two.
Digital input value: 32000 ~ 32000.
Analog output voltage: DC - 10 - 10V.
Digital input value: 0 ~ 32000.
Analog output current: DC0 ~ 20mA.
Without using a special program to create the waveform, can reduce the programming time.
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed output flow simulation waveform.
The analog output module has the function of registering arbitrary waveform data to the module, and continuously executing the analog output according to the set conversion cycle.
Execute the analog quantity (torque) control of stamping machine and injection molding machine, can automatically output the control waveform,
Through the process of high speed, smooth control. In addition, only prior to the waveform data are registered in the module,
Can easily control the analog waveform, so the production line control, such as repetitive control,
Capacity: 8MB.Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: 6.0mA.
Response time: 5 S ~ 70ms.
Common way: 8 point / public end (positive public end).
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input module is the most used module in the control system R60DA16-G.
According to the input voltage, the input points of different, choose the most suitable user needs of the module
R60DA16-G
1 modules are equipped with a variety of functions.
Can be through a single input module to 1 points for the unit to set the high speed response, interrupt input function.
In addition, the public end of the module can be freely selected as the common end of the positive pole and the negative pole R60DA16-G.
It is not necessary to use different modules according to the input specifications and functions, and reduce the number of modules,
Therefore slot occupied quantity can be reduced by 20% than in the past, the deployment cost can be reduced by 60% compared with the previous. Output points: 16 points.
Output form: Transistor (source) output.
Rated open and close voltage, current: - R60DA16-G.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.5A/ point.
Response time: 1ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 320K (security program: 40K).
Program memory: 1280K.
Soft element / tag memory: 2306K.
Data memory: 20M.
Integrate security functions into the control system.
Can be used in the previous iQ-R MELSEC series module as a general control purposes,
Use on the same substrate, it can be used to construct a hybrid system with general control and safety control.
Moreover, IE Field CC-Link network can be integrated with general communication and secure communication,
Ethernet cable can also be used in secure communication,
No need to use a dedicated cable, etc..
Unified program development environment
Whether the general control procedures or safety control procedures, can be integrated into 1 Engineering documents,
Unified management by Works3 GX R60DA16-G. The troublesome operation can save more than one project file management.
When you create a security controll program, you are also the same as when you create a general control program,
Various features of GXWorks3 can be developed using the support program R60DA16-G.