Analog input channel number: 8CH.
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C: plus or minus 0.3%.
Temperature coefficient.
Conversion speed: 80 s/CH.
Channel to channel insulation.
Absolute maximum input: plus or minus 15V.
External wiring connection mode: 18 point screw terminal.
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Analog input current: -.
Digital output value: -.
16 bit high resolution (1/32000).
No program can perform scaling and conversion operations.
The most suitable for the requirements of speed and accuracy of the detection equipment.
Easy to filter high frequency interference.
Execute event driven programs via alarm output.
Through the engineering software, the output of arbitrary analog waveform data.
Works3 GX can be used to easily set the critical value of the input and output signals.
Can quickly detect the abnormal signal, so it can shorten the downtime, reduce maintenance costs.
Channel insulation can ensure the accurate signal transceiver.
Isolation amplifiers are not required to prevent inter channel current and interference current.
Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: 6.0mA.
Response time: 5 S ~ 70ms.
Common way: 8 point / public end (negative public end).
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input module is the most used module in the control system R60ADV8.
According to the input voltage, the input points of different, choose the most suitable user needs of the module
R60ADV8
1 modules are equipped with a variety of functions.
Can be through a single input module to 1 points for the unit to set the high speed response, interrupt input function.
In addition, the public end of the module can be freely selected as the common end of the positive pole and the negative pole R60ADV8.
It is not necessary to use different modules according to the input specifications and functions, and reduce the number of modules,
Therefore slot occupied quantity can be reduced by 20% than in the past, the deployment cost can be reduced by 60% compared with the previous. "Enter points: 64 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 4 R60ADV8. 0mA.
Response time: 0.1 ~ 70ms.
Common way: 32 point / public end.
Interrupt function: have.
External wiring connection: 40 pin connector two.
Easily connect input and output terminals with high density.
An input / output module with 16 points, 32 points, 64 points is provided.
According to the user system to select the most suitable models, help to save space and cost.
The terminal row is compatible with the Q series, and can be used directly by the terminal of the existing system.
Therefore, the wiring cost can be reduced when the system is updated.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LEED, can easily confirm the status of the ON/OFF R60ADV8.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, throough the switch to switch to display the input and output number R60ADV8.
In addition, serial number tag in the front of the module, can be easily recognized. "