MITSUBISHI QY40P Product information and technical parameters: Brand:
MITSUBISHI
Name: Transistor output module (drain type)
Model: QY40P
Output points: 16 points.
Output voltage and current: 12~24V 0.1A/; DC point; 1.6A/ common.
OFF leakage current: 0.1mA;
Response time: 1ms; 1 point 16 public end; leaky type.
18 point terminal station
With heat protection.
With short circuit protection.
With the surge absorber.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
Input / output points: 256 points.
Number of input and output elements: 8192.
Program capacity: 10 K step.
Processing speed: 0.12 s.
Program memory capacity: 40 KB.
Support USB and RS232.
Unable to install memory card.
Own floor 5 slot.
Ultra high speed processing, production time is shortened, better performance QY40P.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time QY40P
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias QY40P.
High speed and high precision data processing.
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0.014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula QY40P. Control axis: maximum 32 axes.
Compact size and space saving.
Using the same hardware structure and MELSEC-Q series PLC, to achieve the same product installation area, the size of the industry.
Using 12 slot substrate, more space and cost savings.
Can share PLC MELSEC-Q power module, substrate, and I/O module.
The control process can be assigned to each CPU module in the multi CPU system, which is equivalent to the intelligent control system.
In PC (Computer Personal) CPU.MODBUS/TCP Master slave station.
10BASE-T/100BASE-TX.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage funcction, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication QY40P.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment QY40P. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)