LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
Q81BD-J71GP21S-SX IE CC-Link controller network

MITSUBISHI Q81BD-J71GP21S-SX Product information and technical parameters:
Brand: MITSUBISHI
Name: IE CC-Link controller network
Model: Q81BD-J71GP21S-SX
Express PCI bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
With external power supply function.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.

5 slots.
The main substrate needs to be equipped with CPU and power supply.
Support for high speed communication between multi CPU.
Requires 1 power modules.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q81BD-J71GP21S-SX Q81BD-J71GP21S-SX
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control Q81BD-J71GP21S-SX. Control axis: maximum 8 axes.
Greater flexibility.
PLC control and motion control using independent CPU, optimize the system configuration.
More than 4 CPU modules can be freely selected in multi CPU system.
MITSUBISHI SSCNET control function.
By using the high speed serial communication mode, we can easily construct the synchronization system of the servo motor.
The motion controller and the servo amplifier can be quickly connected by a connector, and the connection is simplified Q81BD-J71GP21S-SX.
Each 1 CPU can control up to 32 axes at the same time.
Can control the small capacity from 10W to 55KW large capacity servo motor.
Through the use of digital oscilloscope function, can be used to control the power distance, speed, position and other motor information monitoring.Input points: 32 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 points and 1 common ends.
Common anode.
Output points: 32 points.
Output voltage and current: DC12-24V; 0.1A/ point; 2A/ common.
Response time: 1ms.
1 point 32 public end, leakage type; 40 pin connector.
With thermal protection.
With short circuit protection.
With the surge absorber.
With the help of sample tracking function, the starting time is shortened
By using the sampling and tracking function, it is convenient to analyze the data when the fault occurs,
Testing procedures for the time, etc., can shorten the time of failure analysis and start-up time.
In addition, the multi CPU system also helps to determine the data transceiver time between the CPU module.
Can be used to analyze the data collected by programming tools,
In the form of charts and trend charts, the data changes of the bit soft element and the word soft element can be easily displayed.
And the sampling tracking results can be stored in LogViewer GX form CSV,
By recording data display and analysis tool LogViewer GX to display.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the tradittional 32K word,
And to achieve the extension to the file register to all regions of the file register Q81BD-J71GP21S-SX.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured daata (array),
The speed has been improved Q81BD-J71GP21S-SX.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.


...More relevant models >>>>