Enter points: 64 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: 64 points).
External wiring connection: 40 pin connector two.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on.

Convert connector to screw relay terminal.
The action of the signal of the conversion module is shown in the light of the lamp.
Negative common end with display. Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have LX42C4-CM.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points) LX42C4-CM
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch LX42C4-CM.
Communication protocol is a standard Modbus protocol or custom protocol. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Input points: 32 points.
Rated input voltage: DC24V.
Common way: 32 point / public end LX42C4-CM.
Input / output occupied points: 32 points (I/O distribution: 32 points).
External wiring connection mode: 40 pin connector.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on. Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth ccontinuous analog output LX42C4-CM.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period LX42C4-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.