L26CPU-PBT cpu module
MITSUBISHI L26CPU-PBT Manual And Instructions
L26CPU-PBT datasheetPDF datasheet
L26CPU-PBT Common InstructionsProgramming Manual
L26CPU-PBT Special InstructionsProgramming Manual
L26CPU-PBT Application FunctionsProgramming Manual
L26CPU-PBT Common InstructionsProgramming Manual
L26CPU-PBT Structured Text(ST)PROGRAMMING Guide Book
L26CPU-PBT Structured TextProgramming Manual
L26CPU-PBT MELSAP-LProgramming Manual
L26CPU-PBT Bulit-in I/O FunctionUser's Manual
L26CPU-PBT Structured TextProgramming Guide
L26CPU-PBT PID Control InstructionsProgramming Manual
L26CPU-PBT Special InstructionsProgramming Manual
L26CPU-PBT Common InstructionsProgramming Manual
L26CPU-PBT Application FunctionsProgramming Manual
L26CPU-PBT ApplicationUser's Manual

MITSUBISHI L26CPU-PBT Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L26CPU-PBT
"Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "

Number of input channels: 4ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value L26CPU-PBT.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup L26CPU-PBT
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the range of the set range L26CPU-PBT.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter range extension
Range of scalable input range.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected. Convert connector to screw relay terminal L26CPU-PBT.
According to the location of the connection equipment distribution module. Positive common end use. Input points: 16 points.
Rated input voltage: AC100 ~ 120V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computter,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L26CPU-PBT L26CPU-PBT.