L26CPU-P cpu module
MITSUBISHI L26CPU-P Manual And Instructions
L26CPU-P datasheetPDF datasheet
L26CPU-P Common InstructionsProgramming Manual
L26CPU-P Special InstructionsProgramming Manual
L26CPU-P Application FunctionsProgramming Manual
L26CPU-P Common InstructionsProgramming Manual
L26CPU-P Structured Text(ST)PROGRAMMING Guide Book
L26CPU-P Structured TextProgramming Manual
L26CPU-P MELSAP-LProgramming Manual
L26CPU-P Structured TextProgramming Guide
L26CPU-P PID Control InstructionsProgramming Manual
L26CPU-P Special InstructionsProgramming Manual
L26CPU-P Common InstructionsProgramming Manual
L26CPU-P Application FunctionsProgramming Manual
L26CPU-P ApplicationUser's Manual
L26CPU-P Structured TextProgramming Manual

MITSUBISHI L26CPU-P Product information and technical parameters:
Brand: MITSUBISHI
Name: cpu module
Model: L26CPU-P
"Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "

Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Can be used as a screw relay terminal.The connector is converted to a spring clip terminal row.Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end L26CPU-P.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal L26CPU-P
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L26CPU-P. Number of input channels: 8ch L26CPU-P.
Input current: DC0 ~ 20mA.
Conversion speed: 1ms/ch.
Resolution: 1/8000.
By shifting the function easily when the system starts to fine tune the movement function.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormaal detection function of the input signal which is outside the range of the set range L26CPU-P.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter rannge extension
Range of scalable input range L26CPU-P.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.