LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
GT2710-STBA 10.4 inch touch screen
MITSUBISHI GT2710-STBA Manual And Instructions
GT2710-STBA datasheetPDF datasheet
GT2710-STBA MES Interface Function Manual
GT2710-STBA Microcomputers, MODBUS/Fieldbus Products, PeripheralsConnection Manual
GT2710-STBA Non-Mitsubishi Products 2Connection Manual
GT2710-STBA Non-Mitsubishi Products 1Connection Manual
GT2710-STBA Mitsubishi ProductsConnection Manual
GT2710-STBA MonitorUser's Manual
GT2710-STBA UtilityUser's Manual
GT2710-STBA HardwareUser's Manual
GT2710-STBA SAFETY PRECAUTIONS

MITSUBISHI GT2710-STBA Product information and technical parameters:
Brand: MITSUBISHI
Name: 10.4 inch touch screen
Model: GT2710-STBA
Function: high performance and low price in the middle end model.
Picture size: 10.4 inches.
Resolution: SVGA.
Display: TFT color.
Panel color: black.
Power type: AC100~240V.
The highest level model with multi touch and gesture features.
Specification rich, design at ease.
GT27 standard supports SD memory card and standard equipped with Ethernet, RS-232, RS-422/485, host/device USB interface.
Even in the log, script, alarm, soft component data transmission, such as high load processing period, but also to achieve smooth operation of the screen.
In addition, also supports video, animation playback, video input and RGB input and output, can use all the features of GOT2000.
Can be programmed CPU and other procedures, parameters, such as data storage (backup) to the SD GOT memory card, USB memory.
When the programmable controller fails, batch write back (recovery) program.
1, the human body sensor
People will be able to automatically detect and display the picture.
2, USB interface: device USB (Mini-B USB)
Can connect to the computer to transfer data.
3, USB interface: host USB (USB-A)
GOT data can be transmitted through the USB memory or read log data and other data,
Can also be connected to the USB mouse, keyboard use.
4, the extension of the interface
Communication module and optional module can be installed.
5, Ethernet interface
Up to 4 different manufacturers can be connected to the FA machine.
6, RS-232 interface
Can connect all kinds of FA machine, bar code reader, serial printer.
7, RS-422/485 interface
Can be connected to a variety of FA machines, bar code reader.
8, SD memory card slot
Can save alarm and log data, such as a large number of data.

RS-422 connection (QnA/A/FXCPU direct connection, computer connection, micro computer connection).
No clock function.
Applicable model: A956WGOT. Cable length: 20m.
For connection between FXCPU (MINI-DIN8 pin connector) and GOT.
Connection between FXCPU communication function extension board (MINI-DIN8 pin connector) and GOT GT2710-STBA.
Applicable models: GT16, GT15, GT11, HandyGOT, GT10, GT27, GT25, GT23,, GT21 GT2710-STBA Cable length: 13m.
The connection between the CC-LINK interface unit and the smart GOT.
Applicable model: HandyGOT. 1 channels for analog RGB input.
Applicable model: GT15. Oil resistant cap for 15 inch screen.
Applicable model: GT16. Cable length: 10.6m.
Long distance connection between CPU (A Series) and GOT for QnAS/AnSCPU/ motion controller GT2710-STBA.
Long distance connection between A7GT-CNB and GOT.
Applicable models: GT16, GT15, GT11. Protective film for 5.7 inch screen.
Scrub, 5.
Applicable model: GT15. Features: high cost of second models.
Picture size: 10.4 inches.
Resolution: VGA.
Display: TFT color.
Panel color: black.
Power type: DC24V.
Specification rich, design at ease
GT23 standard supports SD memory card and standard equipped with Ethernet, RS-232, RS-422/485, host/device USB interface GT2710-STBA.
Support log, one to many connections, FA transparent transmission and other diverse FA machine related functions.
System configuration diagram shows in order to form the connection with the GOT programmable controller system,
Easily confirm module status. In addition, after touching each module,
Can start its corresponding expansion function, to facilitate system maintenance, shorten the time of failure.
1, simple design
In order to cope with the use of a variety of scenarios, to abandon all the nonsense of the decoration, the use of straight tone of the minimalist design.
2, plane body
Surface mining pure plane design, easy to clean. (USB interface at the back)
3, Ethernet interface
Up to 2 different manufacturers can be connected to the FA machine.
4, RS-232 interface
Can connect all kinds of FA machine, bar code reader, serial printer.
5, RS-422/485 interface
Can be connected to a variety of FA machines, bar code reader.
6, USB interface: device USB (Mini-B USB)
Can connect to the computer to transfer data.
7, USB interface: host USB (USB-A)
USB data can be transmitted through the USB memory or read log data, such as the GOT data, but also can be connnected to the use of the mouse, keyboard GT2710-STBA.
8, SD memory card slot
Can save alarm and log data, such as a large number of data.
Can be collected through the GOT programmable controller, temperature regulator and other data, and to chart, list display GT2710-STBA.
Computer analysis can also be used to save the data. Even in the case of a power outage, the log data can be saved to the built-in SRAM.


...More relevant models >>>>