FX5-4AD-ADP Extension adapter
MITSUBISHI FX5-4AD-ADP Manual And Instructions
FX5-4AD-ADP datasheetPDF datasheet

MITSUBISHI FX5-4AD-ADP Product information and technical parameters:
Brand: MITSUBISHI
Name: Extension adapter
Model: FX5-4AD-ADP
Function: 4CH voltage input / current input.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units.

Input and output points: 40 points.
Power supply: DC24V.
Input points: 24 points.
Output points: 16 points.
Output form: transistor output (source).
Power consumption: 25W.
Weight: 0.7KG.
Outline dimension: 130x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features FX5-4AD-ADP.
Applicable to a wide variety of applications FX5-4AD-ADP
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase FX5-4AD-ADP.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. Power supply: 120mA DC5V (PLC internal power supply), 160mA DC24V.
Analog output points: 4 points.
Voltage output: DC-10~10V FX5-4AD-ADP.
Current output: DC0~20mA, 4~20mA.
Weight: 0.2kg.
Dimensions: 55 x 90 x 87.
The resolution of the 4 channel is 15bit binary + symbol 1bit (voltage),
High precision analog output module of 15bit binary (current).
Each channel voltage output (DC-10~10V) or current output (DC0~20mA, DC4~20mA) can be specified,
Mixed use.
With the form of the output and the upper and lower values and other rich features.
FX3UC-4AD can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: transistor.
Power consumption: 20W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules FX5-4AD-ADP.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable FX5-4AD-ADP.