LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FR-HAL-H110K AC reactor
MITSUBISHI FR-HAL-H110K Manual And Instructions
FR-HAL-H110K datasheetPDF datasheet

MITSUBISHI FR-HAL-H110K Product information and technical parameters:
Brand: MITSUBISHI
Name: AC reactor
Model: FR-HAL-H110K
Power: 110kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)

Power: 7.5kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FR-HAL-H110K.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving FR-HAL-H110K MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 0.75kw.
SLD converter rated current: 2.3A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FR-HAL-H110K.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency FR-HAL-H110K.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Superior high efficiency IPM motor.
Output power: 2.2kw.
Rated speed: 1500r/min.
Voltage level: 400V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 30kw.
SLD converter rated current: 62.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power cconsumption FR-HAL-H110K.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FR-HAL-H110K.


...More relevant models >>>>