FR-F842-09620-2-60 Rectifying partial off type frequency converter
MITSUBISHI FR-F842-09620-2-60 Manual And Instructions
FR-F842-09620-2-60 datasheetPDF datasheet

MITSUBISHI FR-F842-09620-2-60 Product information and technical parameters:
Brand: MITSUBISHI
Name: Rectifying partial off type frequency converter
Model: FR-F842-09620-2-60
MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 450kw.
SLD converter rated current: 962A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop.

The operation, monitoring, parameter modification and other operations can be carried out by computer or PLC.Power: 15kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FR-F842-09620-2-60 FR-F842-09620-2-60
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 2.2KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FR-F842-09620-2-60.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-F842-09620-2-60.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 250kw.
SLD converter rated current: 610A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Mirror like ultra fine processing.
In order to adapt to the new material diversification, the machine adopts the most cutting-edge technology, more than ever more slim hard.
In order to be able to realize the fine cutting, grinding on the hard and hard material,
The need foor high-speed operation has become more and more strong FR-F842-09620-2-60.
In order to cope with the increasing demand of logistics, every port in the world has a crane in every day.
A container filled with cargo.
We can achieve a new type of inverrter products under the conditions of low speed and high torque to achieve smooth cargo handling operations,
Carry on the smooth movement to the heavy FR-F842-09620-2-60.