FR-E740-2.2K-CHT 3 phase 400V converter
MITSUBISHI FR-E740-2.2K-CHT Manual And Instructions
FR-E740-2.2K-CHT datasheetPDF datasheet
FR-E740-2.2K-CHT AppliedInstruction manual
FR-E740-2.2K-CHT BASICInstruction manual

MITSUBISHI FR-E740-2.2K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-E740-2.2K-CHT
MITSUBISHI inverter FR-E740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 2.2KW.
Allow short-time overload (200% 3S).
The machine itself does not need to purchase another operating panel.
Provide USB interface to connect with the computer, you can use the FRConfigurator software to set the parameters of the inverter or monitor.
Inverter surface with PU interface, FR-E500 operating panel can be directly connected to the E700 series. The installation dimensions are in full agreement with FR-E500.
Allow side by side installation, saving installation space
Simple maintenance: equipped with comb type wiring board, wiring more convenient, the replacement of the same series inverter, no stitches, as long as the original inverter control terminal.

"Power: 15kw.
Voltage: 400V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit FR-E740-2.2K-CHT.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy FR-E740-2.2K-CHT "MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V FR-E740-2.2K-CHT.
Power: 400kw.
SLD converter rated current: 866A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time FR-E740-2.2K-CHT.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. Power: 11kw.
Voltage: 400V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and redduce the comprehensive cost FR-E740-2.2K-CHT.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. Power: 110kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.999 and above (100% load) FR-E740-2.2K-CHT.
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function.