FR-A840-00126-2-60 Three phase 400V grade frequency converter
MITSUBISHI FR-A840-00126-2-60 Manual And Instructions
FR-A840-00126-2-60 datasheetPDF datasheet
FR-A840-00126-2-60 PLC FUNCTIONProgramming Manual
FR-A840-00126-2-60 DETAILEDInstruction manual

MITSUBISHI FR-A840-00126-2-60 Product information and technical parameters:
Brand: MITSUBISHI
Name: Three phase 400V grade frequency converter
Model: FR-A840-00126-2-60
MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 3.7kw.
SLD converter rated current: 12.6A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Excellent drive performance.
FR-A800 series equipped with the latest high-speed processor. Has better control performance and response speed,
Products to ensure stable and accurate operation in a wide variety of applications.
Enhanced real-time sensorless vector control and vector control functions, can meet the needs of various kinds of machinery and equipment.
For paper, textile, wire, a variety of tape and other products of the extension of the machine processing, linear speed control is essential.
It can respond quickly to the change of production line speed and avoid the phenomenon of uneven winding.
This helps to achieve a stable supply of high quality products.

Superior high efficiency IPM motor.
Output power: 18kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time FR-A840-00126-2-60. Image operation panel equipped with liquid crystal display.MITSUBISHI inverter FR-D740 series FR-A840-00126-2-60
Voltage level: three phase 400V.
Frequency converter capacity: 0.4KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FR-A840-00126-2-60.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-A840-00126-2-60.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which iss mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A840-00126-2-60.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A840-00126-2-60. "