FR-A840-00052-2-60 Three phase 400V grade frequency converter
MITSUBISHI FR-A840-00052-2-60 Manual And Instructions
FR-A840-00052-2-60 datasheetPDF datasheet
FR-A840-00052-2-60 PLC FUNCTIONProgramming Manual
FR-A840-00052-2-60 DETAILEDInstruction manual

MITSUBISHI FR-A840-00052-2-60 Product information and technical parameters:
Brand: MITSUBISHI
Name: Three phase 400V grade frequency converter
Model: FR-A840-00052-2-60
MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 1.5kw.
SLD converter rated current: 5.2A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Excellent drive performance.
FR-A800 series equipped with the latest high-speed processor. Has better control performance and response speed,
Products to ensure stable and accurate operation in a wide variety of applications.
Enhanced real-time sensorless vector control and vector control functions, can meet the needs of various kinds of machinery and equipment.
For paper, textile, wire, a variety of tape and other products of the extension of the machine processing, linear speed control is essential.
It can respond quickly to the change of production line speed and avoid the phenomenon of uneven winding.
This helps to achieve a stable supply of high quality products.

The output signal can open collector output inverter host standard.
Can be from the voltage output terminal (AM0), the current output terminal (AM1) output analog signal (output frequency, output current, etc.).
Can be connected to the 20mA DC or 10V DC meter. "Power: 15kw.
Voltage: 400V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter FR-A840-00052-2-60 FR-A840-00052-2-60
Motor suitable for 5.5 to 37kW. MITSUBISHI inverter FR-E740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 0.75KW.
Allow short-time overload (200% 3S).
The machine itself does not need to purchase another operating panel.
Provide USB interface to connect with the computer, you can use the FRConfigurator software to set the parameters of the inverter or monitor FR-A840-00052-2-60.
Inverter surface with PU interface, FR-E500 operating panel can be directly connected to the E700 series. The installation dimensions are in full agreement with FR-E500.
Allow side by side installation, saving installation space
Simple maintenance: equipped with comb type wiring board, wiring more convenient, the replacement of the same series inverter, no stitches, as long as the original inverter control terminal FR-A840-00052-2-60. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 220KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which iss mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-A840-00052-2-60.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-A840-00052-2-60. "