LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FR-A740-160K-CHT 3 phase 400V converter
MITSUBISHI FR-A740-160K-CHT Manual And Instructions
FR-A740-160K-CHT datasheetPDF datasheet
FR-A740-160K-CHT PLC FUNCTION PROGRAMMING MANUAL
FR-A740-160K-CHT BASICINSTRUCTION MANUAL
FR-A740-160K-CHT AppliedINSTRUCTION MANUAL
FR-A740-160K-CHT TECHNICAL MANUAL

MITSUBISHI FR-A740-160K-CHT Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-A740-160K-CHT
MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 162KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on.

MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-A740-160K-CHT FR-A740-160K-CHT
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FR-A740-160K-CHT. Power: 15kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FR-A740-160K-CHT.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Power: 5.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in tthe FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FR-A740-160K-CHT.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor FR-A740-160K-CHT.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)