LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FR-A720-37K 3 phase 200V converter
MITSUBISHI FR-A720-37K Manual And Instructions
FR-A720-37K datasheetPDF datasheet
FR-A720-37K PLC FUNCTION PROGRAMMING MANUAL
FR-A720-37K BASICINSTRUCTION MANUAL
FR-A720-37K AppliedINSTRUCTION MANUAL
FR-A720-37K TECHNICAL MANUAL

MITSUBISHI FR-A720-37K Product information and technical parameters:
Brand: MITSUBISHI
Name: 3 phase 200V converter
Model: FR-A720-37K
MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 37KW.
Inverter general area of domestic enterprises to occupy more than 80% of the market share,
Production of frequency converter, motor soft starter and other industrial automation control of the manufacturers, the use of heavy-duty design products,
Overload capacity, with super large start and running capacity, improve the automatic detection, protection and control performance,
Can start and control any type of heavy duty motor,
Products have been widely used in metallurgy, mining, paper, chemicals, building materials, machinery, electricity, and construction systems and other industrial transmission areas.

Power: 22kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost FR-A720-37K .
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving FR-A720-37K Power: 22kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor FR-A720-37K .
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling.
MYS type resistor can be used. But please pay attention to the allowable brake use rate FR-A720-37K .
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time FR-A720-37K .
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the correspondinng signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation FR-A720-37K .
Can reduce the power consumption in the stop.


...More relevant models >>>>