FA-TH16YSR20S datasheetPDF datasheet

MITSUBISHI FA-TH16YSR20S Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YSR20S
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on FA-TH16YSR20S FA-TH16YSR20S FA-TH16YSR20S Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Positive common end use. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output FA-TH16YSR20S. AnyWireASLINK master station.
Transmission distance: the longest 200m.
Data input and output: up to 512 points.
Connect up to 128 units.
Enter 256 points, 256 points out of the output.
Connecting the input and output of the sensor to the programmable controller.
Ultra small sensor can be freely configured to control the input and output of 512 points.
In addition, the sensor can be supplied with a AnyWireASLINK transmission line (2 lines) by means of communication,
So as to facilitate additional sensor.
And can also be through the engineering software Works2 GX batch management sensor disconnection detection and from the station module settings, etc.,
Can significantly reduce the engineering hours.
Basic composition.
AnyWireASLINKAnyWireASLINK can be selected according to the load current of 2 wire or 4 wire from the station module.
In addition to the 2 wire type, the loocal power supply can be connected with the 4 wire type mixed use FA-TH16YSR20S.
2 wire type.
The load current is less than that of the hour, by using the non isolated 2 wire type from the station module,
Easy connection without using local power suupply FA-TH16YSR20S.
4 wire type
By using isolated 4 wire type from the station module, the local power supply can be used,
Can support the use of more current load.