LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TH16YRA11 Terminal module
MITSUBISHI FA-TH16YRA11 Manual And Instructions
FA-TH16YRA11 datasheetPDF datasheet

MITSUBISHI FA-TH16YRA11 Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16YRA11
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.

The connector is converted to a screw relay terminal.Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50 FA-TH16YRA11.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0 FA-TH16YRA113,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program.
No need to use ladder diagram conversion program, can reduce the programming time FA-TH16YRA11.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of the redundant frequency components.
Can be selected from low pass filter, high pass filter, medium pass filter FA-TH16YRA11.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened. The connector is converted to a spring clip terminal row.Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector.
The switch input and output module is a device which can collect the inpuut / output of the switch signal,
Digital I/O modules are often called FA-TH16YRA11.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch FA-TH16YRA11.
Communication protocol is a standard Modbus protocol or custom protocol.


...More relevant models >>>>