LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TH16XRA20S Terminal module
MITSUBISHI FA-TH16XRA20S Manual And Instructions
FA-TH16XRA20S datasheetPDF datasheet

MITSUBISHI FA-TH16XRA20S Product information and technical parameters:
Brand: MITSUBISHI
Name: Terminal module
Model: FA-TH16XRA20S
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.

Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control FA-TH16XRA20S.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling FA-TH16XRA20S
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control) FA-TH16XRA20S.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost FA-TH16XRA20S.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs. DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision contrrol FA-TH16XRA20S.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized FA-TH16XRA20S.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.