LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TBS32XY Conversion module
MITSUBISHI FA-TBS32XY Manual And Instructions
FA-TBS32XY datasheetPDF datasheet

MITSUBISHI FA-TBS32XY Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TBS32XY
The connector is converted to a screw relay terminal.

Cable length: 3.0m.
Weight: 0.45kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conductor of electricity or information from one place to another.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover FA-TBS32XY FA-TBS32XY
The cable has the characteristics of internal power and external insulation. Control axis: maximum 4 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points FA-TBS32XY.
Color detecting set: 4 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control.
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program FA-TBS32XY.
Let motion control more simple. Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost FA-TBS32XY.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniiform, to ensure that the control object no local burning or thermal expansion FA-TBS32XY.
No idle running, with energy saving effect, can reduce operating costs.


...More relevant models >>>>