LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
FA-TB8XY4 Conversion module
MITSUBISHI FA-TB8XY4 Manual And Instructions
FA-TB8XY4 datasheetPDF datasheet

MITSUBISHI FA-TB8XY4 Product information and technical parameters:
Brand: MITSUBISHI
Name: Conversion module
Model: FA-TB8XY4
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module.

Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public.
Output form: transistor output (drain).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) FA-TB8XY4 FA-TB8XY4
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged FA-TB8XY4.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible FA-TB8XY4.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Enter points: 64 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: 64 points).
External wiring connection: 40 pin connector two.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host compuuter,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on FA-TB8XY4 FA-TB8XY4.


...More relevant models >>>>