LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
CL2Y8-TP1S2 Spring clip terminal type output module
MITSUBISHI CL2Y8-TP1S2 Manual And Instructions
CL2Y8-TP1S2 datasheetPDF datasheet

MITSUBISHI CL2Y8-TP1S2 Product information and technical parameters:
Brand: MITSUBISHI
Name: Spring clip terminal type output module
Model: CL2Y8-TP1S2
Output type: transistor output, drain type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction.

Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated input voltage / current: DC24V/4mA.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc CL2Y8-TP1S2. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module CL2Y8-TP1S2
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Points: 32 points
.
Rated voltage: DC24V.
Connection type: connector
.
Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to those who require only the ON/OFF control function of the field components, such as digital I/O or pneumatic valve, etc CL2Y8-TP1S2. .
In this type of communication can only be carried out in the bit data.
Remote components: refers to those that require processing of the register data of the field components, such as analog I/O and counters, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication CL2Y8-TP1S2.
Intelligent remote: this type of component is to allow the main station or other stations to access the action, to collect data and control the local PLC station,
GOTS and programmer interface unit are of this type. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. CL2Y8-TP1S2. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 2 wire.
Type of input and output termminal CL2Y8-TP1S2.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.