LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
CL2Y16-TP1M1V MIL connector type output module
MITSUBISHI CL2Y16-TP1M1V Manual And Instructions
CL2Y16-TP1M1V datasheetPDF datasheet

MITSUBISHI CL2Y16-TP1M1V Product information and technical parameters:
Brand: MITSUBISHI
Name: MIL connector type output module
Model: CL2Y16-TP1M1V
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space.

Output type: transistor output, drain type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square CL2Y16-TP1M1V.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative CL2Y16-TP1M1V
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC24V/7mA CL2Y16-TP1M1V.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool CL2Y16-TP1M1V. Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 1 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 line /1 line type.
40 pin connector type (FCN connector type).
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way,, and the timeliness is strong CL2Y16-TP1M1V.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness CL2Y16-TP1M1V.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.


...More relevant models >>>>