LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
AJ65SBTB32-16KDT2 DC input / transistor output module
MITSUBISHI AJ65SBTB32-16KDT2 Manual And Instructions
AJ65SBTB32-16KDT2 datasheetPDF datasheet

MITSUBISHI AJ65SBTB32-16KDT2 Product information and technical parameters:
Brand: MITSUBISHI
Name: DC input / transistor output module
Model: AJ65SBTB32-16KDT2
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool.

Input type: DC input, positive common end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
By embedding the product into the customer base, the remote I/O station can be simply developed.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc AJ65SBTB32-16KDT2 AJ65SBTB32-16KDT2 .
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc AJ65SBTB32-16KDT2. ,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system AJ65SBTB32-16KDT2.
At the same time, the use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information. Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Screw, 2 piece type terminal.
Voltage / current output module.
Number of channels: 2 channels.
Number of stations: 2 stops.
Station type: remote equipment station.
High speed data transfer of up to 10Mbps;
The development of CC-LINK is not onnly to meet the control of high speed remote I/O,
But also to meet the high speed of the field of information control AJ65SBTB32-16KDT2.
In order to achieve this goal, the transmission speed of CC-LINK is compared with that of the previous live netwwork system to add 40 to 10Mbps AJ65SBTB32-16KDT2.
Such a high speed can not affect the speed of the machine control while allowing a large number of data communication.


...More relevant models >>>>