LK Automation Limited LK Automation Limited
Brand: MITSUBISHI
Go Back >> Product Catalogues
A6TBXY54 Connector / terminal conversion module
MITSUBISHI A6TBXY54 Manual And Instructions
A6TBXY54 datasheetPDF datasheet
A6TBXY54 datasheetPDF datasheet

MITSUBISHI A6TBXY54 Product information and technical parameters:
Brand: MITSUBISHI
Name: Connector / terminal conversion module
Model: A6TBXY54
For common cathode input module and leaky type output module (2 line type).

For A6TBXY36/A6TBXY54/A6TBX70E (common cathode; drain type) long 3m.For 32 point I/O. 0.5 square mm (AWG20).Q2MEM-1MBS and Q2MEM-2MBS replacement batteries.Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current A6TBXY54.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock A6TBXY54
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program A6TBXY54. Alarm monitoring is divided into 2 stages of attention alarm and danger alarm.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
In addition, Works2 GX (1 A6TBXY54. 90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data update is improved.
The transmission delay time is shortened, and the synchronous waiting time of the appplication can be shortened A6TBXY54.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish the network can handle large capacity data.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GGP21-SX controller network, common station A6TBXY54. Adapter for mounting DIN guide rail (with anti vibration device).
For Q3*B, Q5*B, Q6*B, Q38RB, Q68RB, Q65WRB.


...More relevant models >>>>