Type: 18 point terminal.
Input / output form: analog voltage and current input.
Number of stations: 1 stops.
Number of channels: 4 channels.
The conversion speed of the analog input module can be selected from 100 mu s/ channel, 400 mu s/ channel and 1 mu s/ channel.
The conversion speed of the analog output module is 100 mu s/ channel.
By combining the analog input module and the expansion module, the switching time can be controlled more precisely
MR-RB34 (trigger conversion function)
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Type: 18 point terminal.
Output form: transistor output, leakage type.
Output points: 16 points.
Rated input voltage / current: DC12/24V (0.5A).
External connection: 1 wire.
By using the output ON number of times, it is convenient to confirm the total number of ON of each output point.
High speed input and output control of a single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. FL-net (OPCN-2) Ver.1.00 interface.
10BASE5 use.Input points: 32 points.
Input voltage: AC200 ~ 240V.
Current: 5mA.
Response time: 55ms.
16 points / a common end.
50 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.