Type: 18 point terminal.
Output form: transistor output, leakage type.
Output points: 16 points.
Rated input voltage / current: DC12/24V (0.5A).
External connection: 1 wire.
By using the output ON number of times, it is convenient to confirm the total number of ON of each output point.
High speed input and output control of a single module can be realized by using first order logic function.
IE CC-Link field network remote equipment station
MR-JCCBL10M-L According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module).
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. QnA/ACPU bus connection.
2 joint.
Applicable models: A985 (-V) /975/970/960GOT. "1 axes, SSCNET connection type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc..
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug.
Saving wiring through SSCNET cable connections while simultaneously,
The length of the total cable distance up to 30m.
In addition, an absolute position system for determining the origin position is supported by the return data set operation of the origin.
No need for the near point block, such as wiring. "DC input points: 8 points.
Input voltage and current: 7mA, DC24V.
Response time: 10ms.
8 point /1 a public side.
Positive / negative sharing.
Output points: 8 points.
Output voltage and current: DC24V, 0.3A/1 point, 2.4A/1 common end.
Response time: 2ms.
8 point /1 a public side.
Output form: transistor output, leakage type.
34 point terminal station.
Number of stations: 2 stops.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
MR-JCCBL10M-L Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-JCCBL10M-L&select=5