Max input / output points: 128 points.
Supply voltage: 100 - 240VAC.
Input points: 64 points.
Output points: 64 points.
Output type: relay.
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time
MR-J3ENSCBL15M-H
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. Analog input points: 2 channels
Voltage input range: DC0~10V, DC0~5V.
Current input range: DC4~20mA.
Resolution of 12 bit binary high precision analog input module.
Can be 2 channel voltage input, or current input. Express PCI bus.
Support japanese.
Ethernet cable.
Linear / star (linear and star can be mixed use)
Field network (control station / common station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
MR-J3ENSCBL15M-H Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3ENSCBL15M-H&select=5