No introductionCC-Link IE field network AnyWireASLINK bridge module.
AnyWireASLINK products can be seamlessly connected to the IE CC-Link field network. Type: HF-KE servo motor, low inertia, low power.
Rated output power: 0.75kw.
Rated speed: 3000r/min.
Electromagnetic brake: there.
Oil seal: No.
Servo motor can make control speed, position accuracy is very accurate,
The voltage signal can be converted to torque and speed to drive the control object
MR-J3BUS1.5M
Servo motor rotor speed is controlled by the input signal, and can quickly response,
In an automatic control system, used as an actuator,
With electromechanical time constant, high linearity, initiating voltage characteristics,
The signal can be converted into a motor shaft on the angular displacement or angular velocity output.
Divided into DC and AC servo motor two major categories, the main features are,
When the signal voltage is zero, the rotation speed increases with the increase of torque.
Wide use.
Machining equipment and machine tool feed.
Used for food, packaging equipment and feeding device.
For textile machinery, etc..
Can improve the performance of equipment.
Servo amplifier terminals are used to reduce the required wiring time.
The connector is located in front of the servo amplifier, which is convenient for cable connection.
The gain adjustment can be easily carried out by the real-time automatic tuning function.
High performance and easy to operate, reduce work load.
Enhanced system cost performance.
High performance, high precision positioning (servo motor encoder resolution: 131072).
High response.
Suppression of vibration by adaptive vibration suppression control.
Using personal computer and servo setup software to optimize tuning.
Has 2 types of interfaces:
Position control and speed control with pulse train interface.
The analog input interface is used for speed control and torque control. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MR-J3BUS1.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3BUS1.5M&select=5