For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 1m.Horizontally placed cable.
Length: 300mm.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation
HC-SFS702 Servo motor series: medium inertia, medium power.
Rated output: 5.0kw.
Rated speed: 2000r/min.
Electromagnetic brake: with.
Shaft end specification: Standard (straight axis).
Characteristics: medium inertia has two types of low speed and high speed, suitable for different applications.
IP level: IP67.
Application example:
1, material handling system.
2, industrial robots.
3, X-Y working table.
The protection level of the HF-SP/HF-JP series servo motor is IP67 (except the shaft part).
Motor capacity selection soft (MRZJW3-MOTSZ111E)
Friendly interface design, only in the mechanical description window input constant and operation mode can choose the best servo amplifier,
The servo motor and the regenerative braking options, but also in the selection window in the selection of linear servo motor and direct drive motor.
Characteristic
(1) 10 typical mechanical transmission structure can be used to choose
(2) user defined operating modes (location and speed control)
(3) in the selection process, the feed speed and torque can be displayed in a graphical format.
(4) the calculation process can be displayed
Can easily calculate the power of the servo motor free software!ABS serial synchronous encoder input can be used: 2 sets of modules / units.
Position detection method: compiled on value (ABS) method.
Transmission mode: serial communication.
Allows you to track target input points: 2.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.
HC-SFS702 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-SFS702&select=5