Output type: transistor output, drain type.
Output points: 32 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module
HC-SFS152BG1 1/6
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 500kw.
SLD converter rated current: 1094A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation.
Can reduce the power consumption in the stop. Max input / output points: 128 points.
Supply voltage: 100 - 240VAC.
Input points: 64 points.
Output points: 64 points.
Output type: relay.
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
HC-SFS152BG1 1/6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-SFS152BG1 1/6&select=5