Cable length: 3 meters
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable. 2 channel.
Input: DC4~20mA (connecting two wire transmitter); DC0~20mA.
Output (resolution): 0~4000. 0~12000.
Conversion speed: 10ms/ channel
HC-MFS/KFS053G2 (1/20)
40 pin connector.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 1.5KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.
HC-MFS/KFS053G2 (1/20) Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HC-MFS/KFS053G2 (1/20)&select=5