Function extension board for RS-422 communication.
DC5V power consumption: 20mA. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 22KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%)
GT16-80PSGW
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: silicon controlled.
Power consumption: 20W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
GT16-80PSGW Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT16-80PSGW&select=5