Ethernet network module 10BASE-T/10BASE5.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment.
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharing concept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few
GT05-MEM-256MC
And MELSECNET/H not only inherited the excellent characteristics of MELSECNET/10,
Also makes the network real-time better, more data capacity,
Further adapt to the needs of the market. Protocol: SLMP, TCP/IP, UDP.
Communication mode: full duplex / half duplex.
At the same time can open a few: 4 connection.
Weight: 0.3kg.
Connect PLC FX3U/FX3UC to Ethernet.
Support fixed buffer storage, communication connection MELSOFT, through the MC communication protocol, e-mail messages.
When connected to the MELSOFT, through the Works2 PLC can achieve the remote maintenance of GX program.
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. 8 axes, open collector output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
GT05-MEM-256MC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=GT05-MEM-256MC&select=5