Station type: Master station.
Maximum number of stations: maximum 16.
Occupied points: 8 points.
Transfer speed: 10Mbps.
Power supply: 240mA DC24V.
Weight: 0.3kg.
FX3U-16CCL-M is the master module of V2 CC-LINK.
The main station can be connected to 8 remote I/O stations, and 8 remote equipment station or intelligent equipment station.
Can be connected to FX3GA, FX3GE, FX3GC, FX3U and FX3UC of the host
FX3U-128BTY-M
Connecting FX3UC, FX3GC requires FX2NC-CNV-IF or FX3UC-IPS-5V. Input type: DC input, positive common end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
By embedding the product into the customer base, the remote I/O station can be simply developed.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently in any place of the world,
Build a remote monitoring management system.
At the same time, the use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information. Drive: MR-H_ACN series built-in positioning function.
Rated output: 0.6KW.
In servo drive speed closed loop,
Rotor speed measurement accuracy is very important to improve the dynamic and static characteristics of the speed control loop.
In order to seek the balance between measurement precision and system cost, incremental photoelectric encoder is generally used as the speed measuring sensor,
The corresponding method is M/T velocity measurement.
Although the M/T measurement method has a certain measurement accuracy and a wide range of measurement,
But this method has its inherent defects,
Mainly includes: the measurement period must be detected at least one complete encoder pulse, limiting the minimum detectable speed.
2 control system for speed control of the timer switch is difficult to maintain synchronization,
Can not guarantee the accuracy of measurement in the situation where the speed change is larger.
Therefore, it is difficult to improve the speed tracking and control performance of servo drive by using the traditional speed loop design method.
FX3U-128BTY-M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX3U-128BTY-M&select=5