Output type: transistor drain.
Output points: 32 points.
Load voltage: DC5/12.
Load current: 0.016A.
Connection: FCN connector.
Common public end points: 32.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order
FX3GE-40MT/DS
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Protective film for 8.4 inch screen.
Transparent, 5.
Applicable model: GT12. Cable length: 5m.
For MR-J2S-700A (4) /CP/CL or less.
Encoder for HC-SFS; HC-LFS; HC-RFS; 2000r/min HA-LFS; HC-UFS servo motor.
-L represents bending life. MITSUBISHI universal AC servo amplifier MELSERVO-JE series.
Rated output: 0.1kw.
Interface: General purpose.
Compatible motor: HG-KN13J-S100, HG-KN13BJ-S100.
MR-JE-A is equipped with a positioning function!
Be able to realize the positioning of the point set list and the way of the program.
At the same time, it also has a simple cam, encoder to follow, mark detection and other equipment can achieve high performance of the advanced functional group.
Without positioning module, the controller can build a positioning system, which can simplify the system.
Command interface using DI/O and RS-422/RS-485 serial communication (maximum 32 axis),
Can simply set the positioning data through the Configurator2 MR. PCI bus.
Support Japanese, English OS.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
FX3GE-40MT/DS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX3GE-40MT/DS&select=5