MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 30.0kw.
SSCNET interface.
Voltage: 3 phase AC400V.
Complete synchronization system with SSCNET high speed serial communication,
The communication cycle between the controller and the servo amplifier is the longest 0.888ms.
Such systems will be able to provide high reliability and high performance.
When connecting the servo system with SSCNET,
In the motion system, the parameters of the servo amplifier and the acquisition of the data will be displayed on the motion controller
FX2N-32MR-DS
Connect a dedicated cable with an amplifier and a controller to form a SSCNET system.
This simple connection method reduces the routing time and helps to prevent noise.
Even in the MELSERVO-J2-SUPER series products using high resolution coding standards, the command frequency is no limit.
It is only necessary to add a battery on the servo amplifier, which can form the absolute value system.
Currently there are more than 1000000 high reliability SSCNET servo amplifier networks in use.Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Cable length: 30 meters.
PC to GOT long distance connection cable.
For connection between GOT and GOT. Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on.
FX2N-32MR-DS Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FX2N-32MR-DS&select=5