Type: HF-KE servo motor, low inertia, low power.
Rated output power: 0.1kw.
Rated speed: 3000r/min.
Electromagnetic brake: No.
Oil seal: have.
Encoder resolution: 131072p/r.
S100 representative: Super MR-E special motor.
KH003 special mark for Super MR-E.
Servo amplifier terminals are used to reduce the required wiring time.
The connector is located in front of the servo amplifier, which is convenient for cable connection
FR-E720S-0.75K
The gain adjustment can be easily carried out by the real-time automatic tuning function.
Wide use.
Machining equipment and machine tool feed.
Used for food, packaging equipment and feeding device.
For textile machinery, etc..
Can improve the performance of equipment.
High performance and easy to operate, reduce work load.
Enhanced system cost performance.
High performance, high precision positioning (servo motor encoder resolution: 131072).
High response.
Suppression of vibration by adaptive vibration suppression control.
Using personal computer and servo setup software to optimize tuning.
Has 2 types of interfaces:
Position control and speed control with pulse train interface.
The analog input interface is used for speed control and torque control. Enter points: 64 points.
Voltage: DC12/24V.
Current: 3/7mA.
Response time: 10ms.
32 points / a common end.
Cathode common.
40 pin connector.
High speed input.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
FR-E720S-0.75K Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=FR-E720S-0.75K&select=5